Traffic lights run on mains electricity. Without backup power, the lamps of a junction go out when the mains fail. An uninterruptible power supply (UPS) is the outdoor device that keeps the junction signalling system running through that failure. This post covers the values in the UPS06 record and the mains side of the controller.
The cabinet
The UPS is supplied in a metal cabinet with a drip-edge roof and a lockable door. The cabinet's sealing rating is IP65.
Switch-over, battery and charging
- Activation time: under 20 ms
- Battery: 12 V 200 Ah deep-discharge VRLA, 1,700 cycles at 50% depth of discharge
- Battery backup time: over 8 hours (typical four-arm intersection)
- Inverter power: 1000 W
- Maximum charging current: 25 A
The record gives the backup time for a typical four-arm intersection. If a junction's real load differs, so does the time; it is a figure to calculate, not the same for every junction.
How the controller watches the mains
The junction controller watches the mains itself. Among the faults that ANTRA's MMU detects and reports are mains voltage and frequency excursions, and power lost and restored. The controller stores and reports these events.
Junctions with no mains connection
Where there is no mains connection at all, signalling runs on solar power; the parts of that arrangement are described in the solar-powered traffic signals post.
Delivered work
The UPS panels requested by Bursa Metropolitan Municipality in 2023 were manufactured and delivered; the work is among the reference projects.