TBUS is a tunnel cyclist warning system. It detects a cyclist at the tunnel entrance from a camera image, warns drivers through two independent warning outputs, and ends the warning from exit detection or a timeout. This page describes the four steps, the control and monitoring options, and the technical data.

Four steps

  • Detection: an area defined in the camera image is analysed with artificial intelligence for bicycle detection.
  • Verification: the continuity of the detection and object tracking are evaluated, and a cyclist request is then created.
  • Warning: the warning outputs are activated according to the set duration and operating mode.
  • Termination: exit detections are evaluated; the warning ends when the active request ends or when the set timeout elapses.

Entry and exit

Entry and exit cameras are evaluated together. Camera placement and warning points are planned to the structure of the tunnel. Image processing and warning control run on site. The control unit passes the event to the exit unit and to the SCADA system, and the event is logged when the cyclist exits.

Warning outputs

There are two independent outputs. The operating mode and flash durations of each are set separately; the warning delay and the request timeout are set for the site. The system's flashers operate from −40 °C to +70 °C and have an IP65 rating.

Local control

  • Local monitoring: the cyclist request, entry and exit counters, camera status and fault information are shown on the panel screen.
  • Maintenance information: communication status, temperature and electrical measurements are shown on the local screen.
  • Operator control: besides camera detection, a request can be created with a field button; the operating mode can be selected; an active request can be ended from the local screen.

Central connection

Over the Ethernet connection, the cyclist request status can be passed to a SCADA system. The operating mode and warning durations can be set remotely, and commands to create a request or end the active request can be sent.

Technical data

  • Supply voltage: 220 V AC, mains frequency 50 Hz.
  • Camera power: PoE through the switch inside the panel.
  • Warning outputs: 2 independent channels.
  • Button input: triggering by an external field button.
  • Communication: Ethernet.
  • Electrical protection: supply and output fuses; residual-current protection.
  • Climate control: fan and heater.